User’s ManualPrintCart
10Chapter 1 Equipment SetupPrinter Installation1. Set the wheel lock on the caster wheel to prevent the PrintCart from moving.2. Lift the spring loade
Electrical Installation11Terminal Hook-Up1. Install the power supply for the terminal in the pocket provided behind the two slot notebook bin. See Fig
12Chapter 1 Operating Limitations5. Close and latch the rear door.Inverter and battery status are indicated on the LED display panel located on the fr
Electrical Installation13120V/60Hz ModelsEight switches are located on the top center of the RV750ULHW inverter/charger front panel. The far left swit
14Chapter 1 Operating Limitations
152 PrintCartOverviewThe PrintCart is a wireless, cordless work platform capable of transporting several pieces of electrically powered equipment to a
16Chapter 2 PrintCart LayoutThe battery charge function is performed in the inverter/charger. When AC line power is applied, the inverter charger auto
17Figure 6. Rear Left View of the PrintCartFigure 7. Display PanelRefuse BinDocument Holder (2)Power Equipment CompartmentRear Loop-Handle and Termina
18Chapter 2 PrintCart LayoutFigure 8. Power Pallet Features and Safety Devices (120V)Inverter Setup SwitchesInverter Display IndicatorExternal Display
19Figure 9. Power Module Features and Safety Devices (230V)AC Input Circuit Breaker (8A)AC Output Circuit Breaker (5A)AC Power InverterCart Equipment
20Chapter 2 PrintCart Layout
213 OperationLine Power OperationWhen the line cord is connected to a wall receptacle, AC line power is transferred by an Automatic Transfer Switch (A
22Chapter 3 Line Power Operation• 120V – as charging progresses, yelow and green bars illuminate individually with each 10-15% increase in charge stat
PrintCart Operating Duration23Battery Power OperationWhen the PrintCart is unplugged from the AC outlet, the power system automatically switches equip
24Chapter 3 Indicator PanelIndicator PanelColored LEDs on the indicator panel displays operational status. The display is arranged in two sections: ba
PrintCart Operating Duration25Figure 13. Discharged Battery, Operating on InverterNOTE: When the battery is discharged, the alarm timer activates (fla
26Chapter 3 Gaining Access To The PrinterIf the cart is unplugged prior to the reset, the timer controlled shutdown will resume from its previous acti
Load Media Or Ribbon27PrintCart FeaturesWheel Brake/LockThe PrintCart is equipped with a wheel brake/lock on one of the front casters. When applied, t
28Chapter 3 PrintCart AccessoriesDocument HoldersA factory or field installable dual document/notebook holder allows local storage of documents. The h
Load Media Or Ribbon29Utility DrawerA utility drawer is available to store up to 8 1/2 x 11” size paper as well as other small items. This allows the
User’s Manual251755-001FPrintCart
30Chapter 3 PrintCart Accessories
314 TroubleshootingSafetyDuring any troubleshooting activities that require access to the power compartment, you must disconnect the input AC power co
32Chapter 4 PrintCart Safety Features• Der Kontakt zwischen positiven und negativen Anschlüsse ist unbedingt zu vermeiden (Kurzschluss). Kurzschlüsse
33• For the 120V PrintCart input, there is a 15 ampere main circuit breaker mounted on the inverter connector panel. It controls all input power to th
34Chapter 4 Troubleshooting GuideNo AC output in battery mode. AC input is not present.1. Battery mode LED (yellow) is off.2. Battery charge is red a
35AC input is connected but not shown as available.1. Line mode LED (green) is off.2. Charger is not operating.Input circuit breaker is tripped (top p
36Chapter 4 Troubleshooting Guide
375 MaintenancePower Equipment AccessGain access to the power equipment through tool latchable doors on the front and rear of the PrintCart. Inside th
38Chapter 5 Power Equipment Access7. Loosen the AC grounding lug and remove the green grounding wire that runs to the PrintCart frame.8. Open the fron
39Battery Subpallet (BSP) Removal1. If the PrintCart is plugged into an AC outlet, disconnect the plug from the outlet.2. Open the rear access door.3.
TrademarksPrintronix is a registered trademark of Printronix, Inc.All other trademarks are the property of their respective owners.Product WarrantyPri
40Chapter 5 Serviceability InspectionServiceability InspectionNOTE: Only trained personnel should perform this inspection/maintenance. Periodically op
41To Replace Batteries1. Lift the protective covers on the battery (-) terminals and remove the bolts and washers holding the cables in place. See Fig
42Chapter 5 Inverter ReplacementFigure 21. Replacing the BatteryInverter ReplacementMake sure other causes for power failure are eliminated before rep
Display Fuse43Fuse ReplacementThere are two fuses on the PrintCart:• Display Panel Fuse – located between the front most battery terminals in an in-li
44Chapter 5 Power Cord ReplacementPower Cord ReplacementThe AC line cord (power cord) is designed to be user replaceable. The connection between the e
Caster Wheels45Wheel ReplacementCaster WheelsRemovalRecommended replacement caster wheels are specified in the repair parts section (see “Spare Parts”
46Chapter 5 Hand Grip ReplacementHand Grip Replacement1. Remove the hand grips by placing your fingertips on the innermost shoulder of the grip and pu
47A SpecificationsPhysical SpecificationsCharacteristicNorth American (120V/60 Hz)European(230V/50Hz)OperatingHeight (SS top/barcode storage) 40 in./4
48Appendix A Electrical SpecificationsElectrical SpecificationsCharacteristicNorth American (120V/60 Hz)European(230V/50Hz)Battery Capacity 2 x 100 Am
49B Wiring Schematics120V/60HzFigure 26. Wiring Schematic for North American Models (120V/60Hz)
1 Quick Start And Setup ... 7Quick Start ...
50Appendix B 230V/50Hz230V/50HzFigure 27. Wiring Schematic for European Models (230V/50Hz)This design concept consists of a 2 part control system. A &
51C Spare PartsDescription Capacity Style Printronix PNBattery, AGM 100 Amp Hr NB Terminal 205235-001Battery Charger (230VAC) 12v @ 45A 230V 50 Hz 205
52Appendix C
53D GlossaryAC Alternating Current, current that reverses direction periodically. The output of the inverter system or a wall receptacle is AC power.A
54Appendix DElectrolyte An ionic solution, usually distilled water and sulphuric acid, that enables the flow of electrons in a battery from the negati
55E Contact InformationPrintronix Customer Support CenterIMPORTANTPlease have the following information available prior to calling the Printronix Cus
56Appendix E Corporate OfficesCorporate OfficesPrintronix, Inc. 14600 Myford Road P.O. Box 19559 Irvine, CA 92623-9559 Phone: (714) 368-2300 Fax: (71
57Numerics120V/60Hz Wiring Schematics, 49230V/50Hz Wiring Schematics, 50AAccessories, 27refuse bin, 27BBarcode Scanner Storage Slot, 28Battery Power O
58Mechanical Installation, 9printer, 10terminal, 9Media Storage Compartment, 28OOperating Limitations, 12Operationbattery power, 23line power, 21Print
59Specificationselectrical, 48physical, 47Startup, 11Subpallet Removal, power equipment, 37Supplies Department, 55TTerminalhook-up, 11installation, 9T
5 Maintenance... 37Power Equipment Access...
60
251755-001F*251755-001*
71 Quick Start And SetupQuick StartUnpackingWARNINGDismounting the cart from the pallet requires strength. Two people is recommended for the task.1. P
8Chapter 1 Quick Start7. If necessary set the caster brake on the PrintCart.8. Cut the shipping restraint tie wraps on all turnbuckles. 9. Insert a sc
Safety Inspection9Safety Inspection1. Inspect the PrintCart for damage that may have occurred during shipment.2. Open the power compartment door and v
Kommentare zu diesen Handbüchern